Login / Signup

Measuring the effects of structural turnout suits on firefighter range of motion and comfort.

Izabela Ciesielska-WróbelEmiel A DenHartogRoger Barker
Published in: Ergonomics (2016)
Range of motion (ROM) can be restricted by wearing stiff and bulky clothing. This is particularly true of firefighter suits that are constructed using fabric layers to provide thermal protection from fire. This study developed an evaluation technique to quantify the loss of mobility associated with wearing firefighters' protective suits that were deliberately selected to represent similar ergonomic design features. The ROM of 10 firefighters was measured using electro-goniometers attached to their bodies while they wore uniforms and a reference outfit, and performed specific movements. The most restrictive uniform is the Bulky suit that contained additional layers of materials in sleeves and on the knees. The Traditional Suit was more ROM restrictive than Ergonomic. The subjective evaluation of suits supported the objective assessments provided by the electro-goniometers. A 3-D body scanning technique was employed to establish a correlation between the bulkiness of firefighter outfits and subject ROM. Practitioner Summary: This study presents a methodology for measurements of range of motion (ROM) in firefighters wearing personal protective equipment (PPE). Even small differences in designs of PPE may impact firefighters' ROM, which can be detected by electro-goniometers providing measurements if they are attached along the joint to measure limb angular movement.
Keyphrases
  • high speed
  • high resolution
  • wastewater treatment
  • mass spectrometry
  • depressive symptoms
  • sleep quality