Prognostic impact of postprocedure stroke volume in patients with low-gradient aortic stenosis.
Yugo NaraAkihisa KataokaYusuke WatanabeNakashima MakotoHirofumi HiokiHideyuki KawashimaNagura FukukoKen KozumaShinichi ShiraiNorio TadaMotoharu ArakiToru NaganumaFutoshi YamanakaHiroshi UenoMinoru TabataKazuki MizutaniAkihiro HigashimoriKensuke TakagiMasanori YamamotoKentaro HayashidaPublished in: Open heart (2019)
Post-TAVI SVi is a better predictor of cardiovascular mortality than pre-TAVI SVi in patients with symptomatic low-gradient severe AS. Low-flow and low-normal-flow status (35≤ SVi <40 mL/m2) require careful management after TAVI.