Login / Signup

Retrospective Study Comparing Topography-Guided and Wavefront-Optimized LASIK Procedures in a Single Center.

Sheri L RowenTom ToomaNgoc TrieuBrad J Hall
Published in: Clinical ophthalmology (Auckland, N.Z.) (2024)
Topography-guided and wavefront-optimized treatment profiles both provided excellent refractive results. A higher percentage of eyes that were treated using Contoura with Phorcides achieved 20/16 or better unaided distance vision compared to eyes receiving a wavefront-optimized treatment plan.
Keyphrases
  • optical coherence tomography
  • combination therapy
  • smoking cessation