The effect of clinical face shields on aerosolized particle exposure.

Ian T ChaoSarah LeeJason BrenkerDerrick WongCaitlin LowMathilde R DesselleAnne BernardTuncay AlanZoe Keon-CohenJasamine Coles-Black
Published in: Journal of 3D printing in medicine (2023)
Significant reductions in particle concentrations were measured after the application of vented and enclosed face shields. Face shields appear to reduce the concentration of aerosolized particles that HCWs are exposed to, thereby potentially conferring further protection against exposure to aerosolized particles in an operating theatre environment.