Clinical outcome and procedural safety of patients with M2-occlusions undergoing ET are comparable to those of patients with M1-occlusions. Clinical outcome of patients with M1-occlusions undergoing ET is primarily influenced by the initial neurological deficit and the collateralization of the occlusions. By contrast, clinical outcome in patients with M2-occlusions undergoing ET is more multifactorial.