Impact of Apparatus and Adapter on In vitro Drug Release of Ophthalmic Semisolid Drug Products.
Catheleeya MekjaruskulAndré O'Reilly BeringhsBin QinYan WangPallabita ChowdhuryXiuling LuPublished in: Pharmaceutical research (2023)
USP apparatuses and sample adaptors are critical considerations for IVRT. Two-sided semisolid adapter provides higher cumulative release, facilitating the discrimination between low drug content ophthalmic ointment formulations with good sensitivity and repeatability without affecting the drug release rate.