Login / Signup

Iatrogenic inner ear dehiscence associated with lateral skull base surgery: a systematic analysis of drilling injuries and their causal factors.

Nir Ben-ShlomoJagadeesan JayenderJeffrey P GuenetteCarleton Eduardo Corrales
Published in: Acta neurochirurgica (2023)
Inappropriate drill depth, errant lateral drilling, inadequate drill trajectory, or a combination of these led to iatrogenic IED. Image-based segmentation, individualized 3D anatomical model generation, and geometric and volumetric analyses can optimize operative plans and possibly reduce inner ear breaches from lateral skull base surgery.