A Sensitive Assay for Unbound Docetaxel Using Ultrafiltration plus HPLC-MS and Its Application to a Clinical Study.

David WangNatalie Hughes-MedlicottLilian KlinglerYi WangNoelyn HungStephen DuffullTak HungPaul GlueAlbert QinRudolf KwanWing-Kai ChanChristopher Jackson
Published in: Pharmaceutics (2024)
A validated sensitive assay was developed with an LLOQ of 0.084 ng/mL using 485 µL of human plasma. The sensitivity of the assay allowed quantification of unbound docetaxel concentrations in an early-phase oDox+E clinical study to compare it against IV docetaxel using pharmacokinetic modelling. Successful development of oDox+E represents an opportunity to replace the current IV docetaxel regimen with an oral regimen with lower cost, decreased side effects, and improve patient quality of life and experience.