Risk factors associated with loss of variable-thread tapered implants: A retrospective observational study of 1-5 years.
Yangbo XuTie LiuMengna LinAntian XuXiaoting ShenFu-Ming HePublished in: Clinical oral implants research (2023)
Variable-thread tapered implants could reach an acceptable survival rate in clinical practice. Non-submerged implant healing was associated with early implant loss; male gender, periodontitis, implant length <10 mm, and overdenture would significantly increase the risk of late implant loss.