Catheter ablation of left atrial arrhythmias on uninterrupted oral anticoagulation with vitamin K antagonists: What is the relationship between international normalized ratio, activated clotting time, and procedure-related complications?

Marc KottmaierFelix BourierVerena SemmlerMartha TelishevskaKatharina Koch-BüttnerCarsten LennerzSarah LengauerMarielouise KornmayerElena RoussevaStephanie BrooksAmir BrkicChristian GrebmerChristoph KolbGabriele HesslingIsabel DeisenhoferTilko Reents
Published in: Journal of cardiovascular electrophysiology (2017)
There is only a weak correlation between INR, intraprocedural ACT, and intraprocedural heparin requirements. Periprocedural target ACT of 250-300 seconds seems safe and does not increase periprocedural bleeding and thromboembolic complications in patients undergoing RF ablation on uninterrupted phenprocoumon therapy.