Login / Signup

Impact of new operational dosimetric quantities on individual monitoring services.

Marco CaresanaL GarlatiG ZorloniRolf BehrensThomas OttoG MinchilloF Rossi
Published in: Journal of radiological protection : official journal of the Society for Radiological Protection (2021)
The new operational dosimetric quantities framework, proposed in the ICRU95 report, has stimulated the scientific community to start investigations that aim to assess its impact on radiation protection practices. As part of this effort, the present study describes an inter-comparison exercise among individual monitoring services (IMSs) on passive whole-body dosimetry. The inter-comparison is performed in terms of both the existing operational dose quantityHp(10)and its proposed replacementHp, to allow an evaluation of the actions that may be necessary to adapt dosimetry systems to the proposed quantity. For two of the tested IMSs, simple modifications to the detector response function, or the dose calculation algorithm, were sufficient to obtain results within acceptable limits. However, these approaches are not sufficient to give a level of performance comparable to that achieved in terms ofHp(10). This may require a modification to dosemeter design.
Keyphrases
  • monte carlo
  • healthcare
  • primary care
  • mental health
  • radiation therapy
  • machine learning
  • high intensity
  • deep learning
  • magnetic resonance imaging
  • computed tomography
  • radiation induced
  • affordable care act