Login / Signup

Treatment of Pathologic Peritrochanteric Fractures Using Sliding Hip Screws Augmented with Cerclage Reconstruction Plates.

Ying-Kuei KuoHsuan-Yu ChenYuan-Fuu LeeTing-Chun HuangTsung-Han YangYu-An ChenRong-Sen Yang
Published in: Journal of clinical medicine (2021)
We proposed a new method to augment the traditional sliding hip screw (SHS) with cerclage reconstruction plates to treat pathologically impending and actual peritrochanteric fractures as well as to revise open reductions and internal fixations to increase the construct strength against the shearing force, thus reducing the implant failure rate. In this retrospective study, patients with peritrochanteric pathology with at least two years of follow-up who underwent augmentation with cerclage reconstruction plates (modified SHS) and conventional SHS between 1 May 2015 and 31 May 2017 were divided into groups A (n = 12) and B (n = 28), respectively. Demographic data, surgery duration, blood loss, complications, and local radiotherapy were analyzed. The average surgery duration was significantly longer in group A (p = 0.013). The estimated intraoperative and perioperative blood losses were not significantly different between the groups. The implant survival rates were not significantly different under competing risk analysis. The success rate of a revision surgery with modified SHS was excellent, and implant survival time was >2 years, as observed with the previous SHS constructs. Subtrochanteric region involvement and a postoperative visual analog scale ≥4 could be risk factors of implant failure and revision surgery. This technique can be an alternative treatment for difficult pathologic peritrochanteric fractures, especially those with previous plating failure.