Thulium fibre laser vs holmium: yttrium-aluminium-garnet laser lithotripsy for urolithiasis: meta-analysis of clinical studies.
Michael E ChuaAdam BobrowskiIhtisham AhmadJin Kyu KimJan Michael SilangcruzMandy RickardArmando LorenzoJason Y LeePublished in: BJU international (2022)
Overall, there was no between-group difference for the SFR. However, compared to Ho:YAG with no pulse modulation, TFL rendered a better SFR. Shorter OT and LUT, a lesser degree of retropulsion, and a better ablation rate were noted in favour of the TFL. There was no overall between-group difference for composite postoperative complication rate, ablation efficiency, total energy usage, and hospital stay. Currently, the available clinical evidence was assessed to be of very low certainty.