Screening for hemodialysis graft stenosis and short-term thrombosis risk: A comparison of the available tools.
Nicola TessitoreGiovanni LipariAlberto ControFrancesca MorettiGiancarlo MansuetoAlbino PoliPublished in: The journal of vascular access (2019)
Our comparative study showed that an effective screening for graft stenosis and short-term thrombosis risk can rely on Qa surveillance alone, and suggested that avoiding acute hypotension and correcting stenosis at QaU < 1000 mL/min or QaD < 1300 mL/min can contain thrombosis risk.