Login / Signup

Porosity Effect of Polystyrene Membranes on Desalination Performance: A Combined Experimental and Numerical Heat and Mass Transfer Study in Direct Contact Membrane Distillation.

Haneen AbdelrazeqMajeda Khraisheh
Published in: Polymers (2023)
Membrane distillation (MD) is a thermal-based membrane operation with high potential for use in the treatment of aqueous streams. In this study, the linear relationship between the permeate flux and the bulk feed temperature for different electrospun polystyrene membranes is discussed. The dynamics of combined heat and mass transfer mechanisms across different membrane porosities of 77%, 89%, and 94%, each with different thicknesses, are examined. The main results for the effect of porosity with respect to the thermal efficiency and evaporation efficiency of the DCMD system are reported for electrospun polystyrene membranes. A 14.6% increase in thermal efficiency was noted for a 15% increase in membrane porosity. Meanwhile, a 15.6% rise in porosity resulted in a 5% increase in evaporation efficiency. A mathematical validation along with computational predictions is presented and interlinked with the maximum thermal and evaporation efficiencies for the surface membrane temperatures at the feed and temperature boundary regions. This work helps to further understand the interlinked correlations of the surface membrane temperatures at the feed and temperature boundary regions with respect to the change in membrane porosity.
Keyphrases
  • risk assessment
  • tissue engineering
  • climate change
  • ionic liquid
  • human health