Intraocular lens power calculation formulas accuracy in combined phacovitrectomy: an 8-formulas comparison study.
Carlos Diogo Hipólito-FernandesMaria Elisa LuísDiogo MaleitaPedro GilVitor MaduroLívio CostaNuno MarquesJoão BrancoNuno AlvesPublished in: International journal of retina and vitreous (2021)
Surgeons must be careful regarding IOL power selection in phacovitrectomy considering the systematic myopic shift evidenced-constant optimization may help eliminating such error. Moreover, newly introduced formulas and calculation methods may help us achieving increasingly better refractive outcomes both in cataract surgery alone and phacovitrectomy.