Prospective Multicenter Diagnostic Performance of Technologist-Performed Screening Breast Ultrasound After Tomosynthesis in Women With Dense Breasts (the DBTUST).
Wendie A BergMargarita L ZuleyThomas S ChangTerri-Ann GizienskiDenise M ChoughMarcela Böhm-VélezDanielle E SharekMichelle R StrakaChristiane M HakimKimberly S HarnistCathy S TymaAmy E KellyUzma WaheedGolbahar HoushmandBronwyn E NairDilip D ShindeAmy H LuAndriy I BandosJeremy M BergNicole B LettiereMarie A GanottPublished in: Journal of clinical oncology : official journal of the American Society of Clinical Oncology (2023)
Overall added cancer detection rate of US screening after DBT was modest at 19/17,552 (1.1/1,000; CI, 0.5- to 1.6) screens but potentially overcomes substantial increases in false-positive recalls and benign biopsies.