Login / Signup

Locally advanced rectal cancer: 3D diffusion-prepared stimulated-echo turbo spin-echo versus 2D diffusion-weighted echo-planar imaging.

Qinwei ZhangPetra J van HoudtDoenja M J LambregtsBaukelien van TriestMarnix P M KopBram F CoolenGustav J StrijkersUulke A van der HeideAart J Nederveen
Published in: European radiology experimental (2020)
DPsti-TSE provided geometrically less distorted rectal cancer diffusion-weighted images. However, the image quality of DW-EPI over DPsti-TSE was referred on the basis of several image quality criteria. A significant bias in tumour ADC values from DPsti-TSE was present. Further improvements of DPsti-TSE are needed until it can replace DW-EPI.
Keyphrases