Management of abdominal wound dehiscence: update of the literature and meta-analysis.
Andreas DenysThomas MonbailliuMathias AllaeysFrederik BerrevoetGabriëlle H van RamshorstPublished in: Hernia : the journal of hernias and abdominal wall surgery (2020)
Included studies were of low to very low quality. The use of synthetic mesh results in a significantly lower rate of incisional hernia, whereas SSI rate was comparable to primary suture repair.