Locating and Imaging Fiber Breaks in CFRP Using Guided Wave Tomography and Eddy Current Testing.
Dario J PasadasMohsen BarzegarArtur L RibeiroHelena Geirinhas RamosPublished in: Sensors (Basel, Switzerland) (2022)
In this paper, guided Lamb wave tomography and eddy current testing (ECT) techniques were combined to locate and evaluate fiber breaks in carbon-fiber-reinforced plastic (CFRP) structures. Guided wave testing (GWT) and computed tomography (CT) imaging were employed to quickly locate fiber breaks in the CFRP plate. From B-scans performed along two different fiber orientations (0 and 90 degrees), parallel-beam projections of different features were extracted from the guided wave signals, using signal-processing techniques (such as wavelet and Hilbert transforms) and statistical functions (such as skewness and kurtosis). The parallel-beam projections of each individual feature were used as input in computed tomography imaging reconstruction to approximately estimate the location of fiber breaks. From the obtained reconstructed images, image-fusion techniques were applied to get complementary information from multiple source images into one single image. After locating the fiber breaks, C-scans were performed in the vicinity of the damage, using an ECT probe with double excitation configuration to evaluate the condition of the fiber break.