Dual-Encoded Affinity Microbead Signature Combinatorial Profiling for Acute Myocardial Infarction High-Sensitivity Diagnosis.

Luxuan HeJiacheng WuZhun LinYuanqing ZhangPeiqing Liu
Published in: ACS sensors (2024)
The early diagnosis of acute myocardial infarction (AMI) is dependent on the combined feedback of multiple cardiac biomarkers. However, it remains challenging to precisely detect multicardiac biomarkers in complex blood early due to the lack of sensitive and specific diagnostic indicators and the low abundance and small size of associated biomarkers with high specificity (such as microRNAs). To make matters worse, spectral overlap significantly limits the multiplex analysis of cardiac biomarkers by fluorescent probes, leading to bias in the diagnosis of myocardial infarction. Herein, we developed a method for simultaneous detection of miRNAs and protein biomarkers using size- and color-coded microbeads that carry signature for target capture. We also constructed a microfluidic chip with different spacer arrays that segregate these microbeads in different chip regions according to their size to produce signature signals, indicating the level of different biomarkers. The signals on the microbeads were hugely amplified by catalytic hairpin assembly and rolling circle amplification. Notably, this strategy enables the simultaneous and in situ sensitive profiling of six kinds of biomarkers via adding two different fluorescent labels, removing the limitations of spectral overlap. We envision that the strategy has great potential for application in clinical diagnosis for AMI.