Phase-rectified signal averaging: correlation between two monitors and relationship with short-term variation of fetal heart rate.
Becky LiuBaskaran ThilaganathanAmarnath BhidePublished in: Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology (2023)
PRSA appears to be equivalent method of fetal assessment to STV, but due to its innate ability to eliminate artefact, PRSA is superior to STV in generating interpretable traces and trace accuracy with NIFECG. These findings raise the possibility of self-applied home or remote fetal heart-rate monitoring with automated reporting to enable increased surveillance in high-risk women without impacting service demand. This article is protected by copyright. All rights reserved.