Login / Signup

Push-Out Method for Micro Measurements of Interfacial Strength in Aluminium Alloy Matrix Composites.

Rafał KozeraAnna BoczkowskaZuzanna D KrawczykPaulina KozeraMaciej SpychalskiMarcin MałekRobert Kosturek
Published in: Materials (Basel, Switzerland) (2021)
The main goal of this work was the evaluation of the interfacial strength of the carbon fibres/aluminium matrix interface dependently on the utilised composite fabrication method, namely high pressure die casting and gas pressure infiltration. In addition, the influence of a Ni-P coating on the C-fibres was investigated. The proposed measurements of the interfacial strength were carried out by means of the "push-out" method. The interfacial strength of the samples fabricated using the high-pressure infiltration method average between 19.03 MPa and 45.34 MPa.
Keyphrases
  • ionic liquid
  • molecular dynamics simulations
  • electron transfer
  • perovskite solar cells
  • high resolution
  • atomic force microscopy
  • single molecule