Agreement between mathematically arterialised venous versus arterial blood gas values in patients undergoing non-invasive ventilation: a cohort study.
Anne-Maree KellySharon KlimStephen E ReesPublished in: Emergency medicine journal : EMJ (2013)
For patients undergoing NIV in an ED, agreement between mathematically arterialised venous values and arterial values was close for pH but only moderate for pCO2. Depending on clinician tolerance for agreement, this method may be a clinically useful alternative to arterial blood gas analysis in the ED.