Login / Signup

Transhepatic forceps biopsy combined with biliary drainage in obstructive jaundice: safety and accuracy.

Audrey FohlenCeline BazilleBenjamin MenahemMarc Antoine JegondayBenoit DupontVincent Le PennecJean LubranoBoris GuiuJean Pierre Pelage
Published in: European radiology (2018)
Implications for patient care: • Percutaneous transbiliary forceps biopsy is technically feasible (100% of tissue sampling in our study) and is a safe technique. • Radiological management combining PTFB plus PTBD may allow diagnosis and treatment of the biliary stricture at the same time. • Sensitivity and accuracy for PTFB reached 78 and 80%, respectively, with a 100% specificity.
Keyphrases
  • ultrasound guided
  • fine needle aspiration
  • minimally invasive
  • structural basis