Assessment of angle closure spectrum disease as a continuum of change using gonioscopy and anterior segment optical coherence tomography.

Jack PhuBrian WongThalia LimMichael Kalloniatis
Published in: Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) (2020)
Our results do not necessarily support the assumption that the ordinal scales used in gonioscopy can be interpreted using an interval scale. We highlight the need for better methods of describing the course and risk of angle closure spectrum disease to identify disease progression and conversion, where gonioscopy remains the gold standard.