Reduction of severe acute respiratory syndrome coronavirus-2 infectivity by admissible concentration of ozone gas and water.
Takayuki MurataSatoshi KomotoSatoko IwahoriJun SasakiHironori NishitsujiTerumitsu HasebeKiyotaka HoshinagaYukio YuzawaPublished in: Microbiology and immunology (2020)
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is causing the global coronavirus disease 2019 (COVID-19) pandemic. Because complete elimination of SARS-CoV-2 appears difficult, decreasing the risk of transmission is important. Treatment with 0.1 and 0.05 ppm ozone gas for 10 and 20 hr, respectively, decreased SARS-CoV-2 infectivity by about 95%. The magnitude of the effect was dependent on humidity. Treatment with 1 and 2 mg/L ozone water for 10 s reduced SARS-CoV-2 infectivity by about 2 and 3 logs, respectively. Our results suggest that low-dose ozone, in the form of gas and water, is effective against SARS-CoV-2.