Login / Signup

Facile synthesis of Cu/Co-ZIF nanoarrays for non-enzymatic glucose detection.

Shupei SunQian DuNianfeng ShiXiaoming LiaoGuangfu Yin
Published in: Nanotechnology (2021)
Cu/Co-ZIF nanoflake arrays on carbon cloth are fabricated by controlling the introducing of Cu2+ions during the growth of Co-ZIF. The Cu/Co-ZIF-20 electrode prepared with 20 mM Cu2+possesses large electrochemically active surface area and bimetallic active sites, which can be revealed by cyclic voltammetry tests. The amperometrici-tmeasurements demonstrate that the Cu/Co-ZIF-20 electrode displays a wide linear range from 0.05 mM to 6.0 mM, and a high sensitivity of 1.03 mA mM-1cm-2. Good selectivity, repeatability and practical applicability indicate its promising application in enzyme-free glucose sensing.
Keyphrases
  • aqueous solution
  • metal organic framework
  • type diabetes
  • blood glucose
  • nitric oxide
  • weight loss