Intraoperative loose flexion gap may restrict postoperative knee flexion after J-curve design posterior-stabilized total knee arthroplasty.
Sachiyuki TsukadaKenji KurosakaMasahiro NishinoHiroyuki OgawaNaoyuki HirasawaPublished in: European journal of orthopaedic surgery & traumatology : orthopedie traumatologie (2019)