CT-guided percutaneous transthoracic needle biopsy for anterior mediastinal lymphoma: the role of PET/CT.

Yura AhnSang Min LeeJooae ChoeNayoung KimSang Young OhKyung-Hyun DoJoon Beom Seo
Published in: Acta radiologica (Stockholm, Sweden : 1987) (2024)
Only inappropriate targeting of the non-viable portion according to PET/CT was an independent risk factor for non-diagnostic results. Acquiring PET/CT scans before biopsy and targeting the viable portion on PET/CT may help improve the diagnostic sensitivity of PTNB.