Improved technology satisfaction and sleep quality with Medtronic MiniMed® Advanced Hybrid Closed-Loop delivery compared to predictive low glucose suspend in people with Type 1 Diabetes in a randomized crossover trial.
Benjamin John WheelerOlivia J CollynsRenee A MeierZara L BettsChris FramptonCarla M FrewenBarbara C GallandNiranjala M HewapathiranaShirley D JonesDenis S H ChanAnirban RoyBenyamin GrosmanNatalie KurtzJohn ShinRobert A VigerskyMartin I de BockPublished in: Acta diabetologica (2021)
These data suggest that AHCL compared to SAP + PLGM mode has the potential to increase treatment satisfaction and improve subjective sleep quality in adolescents and adults with T1D.