Effect of customized abutment taper configuration on bone remodeling and peri-implant tissue around implant-supported single crown: A 3D nonlinear finite element study.

Pongsakorn PoovarodomChaiy RungsiyakullJarupol SuriyawanakulQing LiKeiichi SasakiNobuhiro YodaPimduen Rungsiyakull
Published in: Journal of prosthodontics : official journal of the American College of Prosthodontists (2023)
In conclusion, the abutment taper configuration had a slight effect on bone remodeling but exerted a significant effect on the peri-implant gingiva above the implant platform via hydrostatic pressure. Significant decreases in greatest and average hydrostatic pressures were observed in the peri-implant tissues of Model 30°. However, the results indicate that implant abutment tapering wider than 40° could result in a larger area of excessive hydrostatic pressure in peri-implant tissue, which could induce gingival recession. This article is protected by copyright. All rights reserved.