Comparison of gadolinium-based contrast agents for MR cholangiography in saline, blood and bile: a phantom study.

Johannes M FroehlichLeen MoussaNatalie GuirguisAndreas GutzeitDavid WuSabine Sartoretti-ScheferDow-Mu KohOrpheus KolokythasSimon Matoori
Published in: European radiology experimental (2023)
• Contrast-enhanced magnetic resonance (MR) cholangiography depends on contrast agent type, kinetics, and concentration in bile, • We compared signal intensities of three contrast agents in a bile phantom study. • Gadobenate, gadoxetate, and gadoterate demonstrated different signal intensities at identical concentrations. • Gadoxetate and gadobenate showed high signal intensities on T1-weighted MR sequences.