Login / Signup

Determination of Phenol with Peroxidase Immobilized on CaCO 3 .

Aleksandr L KimAlexey V DubrovskiiEgor V MusinSergey A Tikhonenko
Published in: International journal of molecular sciences (2023)
Phenols are widely used in industries despite their toxicity, which requires governments to limit their concentration in water to 5 mg/L before discharge to the city sewer. Thus, it is essential to develop a rapid, simple, and low-cost detection method for phenol. This study explored two pathways of peroxidase immobilization to develop a phenol detection system: peroxidase encapsulation into polyelectrolyte microcapsules and peroxidase captured by CaCO 3 . The encapsulation of peroxidase decreased enzyme activity by 96%; thus, this method cannot be used for detection systems. The capturing process of peroxidase by CaCO 3 microspherulites did not affect the maximum reaction rate and the Michaelis constant of peroxidase. The native peroxidase-Vmax = 109 µM/min, Km = 994 µM; CaCO 3 -peroxidase-Vmax = 93.5 µM/min, Km = 956 µM. Ultimately, a reusable phenol detection system based on CaCO 3 microparticles with immobilized peroxidase was developed, capable of detecting phenol in the range of 700 ng/mL to 14 µg/mL, with an error not exceeding 5%, and having a relatively low cost and production time. The efficiency of the system was confirmed by determining the content of phenol in a paintwork product.
Keyphrases
  • hydrogen peroxide
  • low cost
  • loop mediated isothermal amplification
  • oxidative stress
  • nitric oxide
  • ionic liquid
  • sensitive detection
  • high resolution