A different surgical approach to cases with zonular weakness or dialysis: sutureless transscleral fixated intraocular lens implantation and stabilization of lens capsule.
Ibrahim TaskinDeniz AltinbayVeli Nusret OzdemirPublished in: International ophthalmology (2020)
The use of this new surgical modification that utilizes capsular tension rings combined with a procedure that secures the sutureless scleral IOL fixation to the capsulorhexis for the treatment of eyes with zonular dialysis in excess of 70° was found to be very successful in the 6 months of follow-up. More cases and longer follow-up periods are required to provide an idea as to whether different complications will develop in such patients.