Influence of restorative margins position on one-stage laser-microgrooved implants-supported single screwed crowns: A clinical, biochemical, and microbiological analysis.

Renzo GuarnieriDario Di NardoGianfranco GaimariGabriele MiccoliLuca Testarelli
Published in: Clinical implant dentistry and related research (2018)
Results showed that the intracrevicular deeper position of the restoration margin does not influence the clinical and biochemical peri-implant parameters. The deeper position of the crown margin is associated with a greater amount of putative periodontal pathogenic microflora colonization.
Keyphrases