A Deep Learning Model to Triage Screening Mammograms: A Simulation Study.
Adam YalaTal SchusterRandy MilesRegina BarzilayConstance D LehmanPublished in: Radiology (2019)
Background Recent deep learning (DL) approaches have shown promise in improving sensitivity but have not addressed limitations in radiologist specificity or efficiency. Purpose To develop a DL model to triage a portion of mammograms as cancer free, improving performance and workflow efficiency. Materials and Methods In this retrospective study, 223 109 consecutive screening mammograms performed in 66 661 women from January 2009 to December 2016 were collected with cancer outcomes obtained through linkage to a regional tumor registry. This cohort was split by patient into 212 272, 25 999, and 26 540 mammograms from 56 831, 7021, and 7176 patients for training, validation, and testing, respectively. A DL model was developed to triage mammograms as cancer free and evaluated on the test set. A DL-triage workflow was simulated in which radiologists skipped mammograms triaged as cancer free (interpreting them as negative for cancer) and read mammograms not triaged as cancer free by using the original interpreting radiologists' assessments. Sensitivities, specificities, and percentage of mammograms read were calculated, with and without the DL-triage-simulated workflow. Statistics were computed across 5000 bootstrap samples to assess confidence intervals (CIs). Specificities were compared by using a two-tailed t test (P < .05) and sensitivities were compared by using a one-sided t test with a noninferiority margin of 5% (P < .05). Results The test set included 7176 women (mean age, 57.8 years ± 10.9 [standard deviation]). When reading all mammograms, radiologists obtained a sensitivity and specificity of 90.6% (173 of 191; 95% CI: 86.6%, 94.7%) and 93.5% (24 625 of 26 349; 95% CI: 93.3%, 93.9%). In the DL-simulated workflow, the radiologists obtained a sensitivity and specificity of 90.1% (172 of 191; 95% CI: 86.0%, 94.3%) and 94.2% (24 814 of 26 349; 95% CI: 94.0%, 94.6%) while reading 80.7% (21 420 of 26 540) of the mammograms. The simulated workflow improved specificity (P = .002) and obtained a noninferior sensitivity with a margin of 5% (P < .001). Conclusion This deep learning model has the potential to reduce radiologist workload and significantly improve specificity without harming sensitivity. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Kontos and Conant in this issue.
Keyphrases
- papillary thyroid
- deep learning
- emergency department
- squamous cell
- artificial intelligence
- electronic health record
- healthcare
- magnetic resonance imaging
- machine learning
- lymph node metastasis
- metabolic syndrome
- pregnant women
- magnetic resonance
- case report
- type diabetes
- human immunodeficiency virus
- dna methylation
- polycystic ovary syndrome
- newly diagnosed
- working memory
- risk assessment
- weight loss
- convolutional neural network
- glycemic control
- virtual reality
- patient reported