We validated a novel criterion for HB capture that is based on the physiological left ventricular activation time as an individualized reference. HB capture can be diagnosed when paced V6 RWPT does not exceed the value obtained during native conduction by more than 12 ms, while longer paced V6 RWPT indicates RVS capture.