Proximal Perineural Femoral Nerve Injection in Pigs Using an Ultrasound-Guided Lateral Subiliac Approach-A Cadaveric Study.
Robert TrujanovicPablo E OteroPeter MarhoferUlrike AuerSilvio KauPublished in: Animals : an open access journal from MDPI (2021)
Desensitizing the femoral nerve (FN) improves pain control in several species undergoing pelvic limb surgeries. Despite its advantages, this method has not yet been described in pigs, although they make an accepted surgical animal model. Based on anatomical dissections, first performed in two pig cadavers, an ultrasound-guided access for localization and perineural infiltration of the FN trunk at the iliopsoas compartment level was specified. The FN was found running between the psoas major and medial portion of iliac muscle. Ultrasonographically, the FN appeared as a hypoechogenic round-oval structure surrounded by a hyperechogenic rim. Technical feasibility and accuracy were assessed in six additional pig cadavers by injecting 0.15 mL kg-1 methylene blue dye bilaterally in direct proximity to the nerve. The needle was inserted caudoventral to the coxal tuber, traversing the ultrasound plane as it progressed towards the FN in dorsomedial direction. Staining of the nerve was evaluated by dissection. The injection was considered effective if the nerve was stained in its entire circumference over a length of 2 cm. FNs of all investigated individuals could be successfully stained. This ultrasound-guided subiliac approach allows feasible and accurate access to the FN and may be useful in producing a successful blockade in vivo.