Skin exposure to the rubber accelerator diphenylguanidine in medical gloves-An experimental study.
Nils HamneriusAnn PonténJonas BjörkChristina PerssonOla BergendorffPublished in: Contact dermatitis (2019)
The use of alcoholic disinfectant increased skin exposure to the rubber accelerator DPG. Even a short duration of use of gloves results in substantial exposure to DPG.
Keyphrases