Novel hyperparallel optical coherence tomography for angle closure assessment: comparison with swept-source OCT and gonioscopy.
Natalia PorporatoBenjamin Y XuBingyao TanYu Q ChangTin A TunShamira PereraRahat HusainChing Lin HoRehena SultanaTin AungLeopold SchmettererPublished in: The British journal of ophthalmology (2024)
HP-OCT showed excellent reproducibility for angle closure assessment and good agreement with SS-OCT and gonioscopy. HP-OCT technology also provides a unique capability to visualise regions around TM and Schlemm's canal, opening new avenues for clinical research of distal outflow pathways.