Which is the Optimal Frozen Elephant Trunk? A Systematic Review and Meta-Analysis of Outcomes in 2161 Patients Undergoing Thoracic Aortic Aneurysm Surgery Using E-vita OPEN PLUS Hybrid Stent Graft versus Thoraflex™ Hybrid Prosthesis.
Amer HarkyMatthew FokMohamad BashirPublished in: Brazilian journal of cardiovascular surgery (2020)
Although there are limited studies available, the available data suggests that mortality and morbidity are lower for the E-vita device in thoracic aortic aneurysm surgery than for Thoraflex™. Long-term data of comparative studies do not yet exist to assess viability of these procedures.