Comparison of high-power and conventional-power radiofrequency energy deliveries in pulmonary vein isolation using unipolar signal modification as a local endpoint.
Koichiro EjimaSatoshi HiguchiKyoichiro YazakiShohei KataokaDaigo YagishitaMiwa KanaiShohei KataokaNobuhisa HagiwaraPublished in: Journal of cardiovascular electrophysiology (2020)
The high-power PVI guided by USM decreased the procedural time and may improve the procedural outcomes without compromising the safety.