Comparative Analysis of Lung Perfusion Scan and SPECT/CT for the Evaluation of Functional Lung Capacity.

Hoon Young SuhSohyun ParkHyun Gee RyooJi-Young KimTae Sung KimJong Mog LeeMoon Soo KimHee Chul YangSeok-Ki Kim
Published in: Nuclear medicine and molecular imaging (2019)
We suggest SPECT/CT as the primary modality of choice for the assessment of the ratio of diseased lung area. Both perfusion scan and SPECT/CT can be used for the prediction of postoperative lung function.