Biomimetic Electrochemical Sensors Based on Core-Shell Imprinted Polymers for Targeted Sunset Yellow Estimation in Environmental Samples.
Sumeet MalikAdnan KhanHamayun KhanGul RahmanNauman AliSabir KhanMaria Del Pilar Taboada SotomayorPublished in: Biosensors (2023)
Magnetic molecularly imprinted polymers (MMIPs) contain the predesigned specialized recognition capability that can be chosen to build credible functional materials, that are easy to handle and have a good degree of specificity. Hence, the given piece of work is intended to design a novel electrochemical sensor incorporating magnetite-based molecularly imprinted polymers. The building materials consisted of a cross-linker (EGDMA), reaction-initiator (AIBN), monomer (methylene succinic acid-MSA), and template molecule (Sunset Yellow-SY dye). MMIPs exhibited a diameter of 57 nm with an irregular shape due to the presence of cavities based on SEM analysis. XRD patterns exhibited crystallinity, as well as amorphous peaks that are attributed to polymeric and non-polymeric frameworks of MMIPs. The crystallite size of the MMIPs from XRD analysis was found to be 16.28 nm based on the Debye-Scherrer's equation. Meanwhile, the FTIR bands showed the synthesis of MMIPs using monomer and methylene succinic acid. The sorption data at the optimized operating conditions (pH 2, sorbent dosage 3 mg, time 18 min) showed the highest sorption capacity of 40 mg/g. The obtained data best fitted to the Langmuir sorption isotherm and followed the pseudo-second-order kinetics. The magneto-sensors were applied for ultrasensitive, rapid, and simple sensing of SY dye. The electrochemical experiments were run at the operating condition range of (scan rate 10-50 mV/s, tads 0-120 s, pH 5-9, potential range 1-1.5 V for CV and 1-1.3 V for SWAdASV). The linear range of detection was set to 1.51 × 10 -6 M to 1.51 × 10 -6 M posing LOD and LOQ values of 8.6242 × 10 -5 M and 0.0002874 M, respectively. The regression analysis value for the calibration was found to be 0.950. Additionally, high adsorption efficiency, selectivity, reusability, and strong structural stability of the magneto-sensors showed potential use for SY detection in real samples. These characteristics make MMIPs a viable electrochemical substrate for the detection of chemical contaminants in the environment and in health-related products.
Keyphrases
- molecularly imprinted
- solid phase extraction
- loop mediated isothermal amplification
- drug delivery
- label free
- photodynamic therapy
- low cost
- cancer therapy
- risk assessment
- human health
- tandem mass spectrometry
- drinking water
- computed tomography
- magnetic resonance
- big data
- real time pcr
- high resolution
- liquid chromatography
- drug release
- room temperature