Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles.
Fernanda FaotAmália Machado BielemannAlessandra Julie SchusterRaissa Micaella Marcelo MachadoAltair Antoninha Del Bel CuryGustavo Giacomelli NascimentoOtacílio Luiz Chagas-JuniorPublished in: BioMed research international (2019)
The IT did not influence the clinical outcomes and the peri-implant immunoinflammatory responses and was weakly correlated with the narrow dental implants primary stability. The observed success rates suggest that the ideal IT for atrophic fully edentulous patients may deviate from the standardized IT of 32 Ncm.