Login / Signup

Bioinspired design and optimization for thin film wearable and building cooling systems.

Jonathan GrinhamMatthew James HancockKitty KumarMartin BechtholdDonald E IngberJoanna Aizenberg
Published in: Bioinspiration & biomimetics (2021)
In this work, we report a paradigmatic shift in bioinspired microchannel heat exchanger design towards its integration into thin film wearable devices, thermally active surfaces in buildings, photovoltaic devices, and other thermoregulating devices whose typical cooling fluxes are below 1 kW/m2. The transparent thermoregulation device is fabricated by bonding a thin corrugated elastomeric film to the surface of a substrate to form a microchannel water-circuit with bioinspired unit cell geometry. Inspired by the dynamic scaling of flow systems in nature, empirically derived sizing rules and a novel numerical optimization method implemented in MATLAB® with COMSOL Multiphysics® are used to maximize the thermoregulation performance of the microchannel network by enhancing the uniformity of flow distribution. The optimized network design results in a 25% to 37% increase in the heat flux compared to non-optimized designs. The study demonstrates the versatility of the presented device design and architecture by fabricating and testing a scaled-up numerically optimized heat exchanger design for building-scale and wearable applications.
Keyphrases
  • heart rate
  • stem cells
  • single cell
  • mesenchymal stem cells
  • cystic fibrosis
  • ionic liquid
  • candida albicans
  • reduced graphene oxide
  • structural basis