Refractive Outcome and 5-Year Capsulotomy Rate of Hydrophobic and Hydrophilic IOLs with Similar Optical Design: A Contralateral Study.
Carlo BellucciPaolo MoraSalvatore A TedescoStefano GandolfiRoberto BellucciPublished in: Ophthalmology and therapy (2023)
In this contralateral comparative study, the hydrophobic and hydrophilic matrix of the IOL similarly influenced the visual and aberrometric outcomes. Also the long-term laser capsulotomy incidence did not statistically differ between groups. The posterior IOL profile, rather than matrix hydrophilia, could consistently influence the posterior capsule opacification.