Effect of radiofrequency on epicardial myocardium after ablation of ventricular arrhythmias from within coronary sinus.
Basar CandemirElif OzyurekKutay VurgunNazli TuranVeysel DuzenHuseyin GoksulukNil OzyuncuSeda KurkluTimucin AltinOmer AkyurekCetin ErolPublished in: Pacing and clinical electrophysiology : PACE (2018)
RF delivery inside the CVS is less likely to produce detectable LGE on CMRI compared to RVOT. This may partially explain less than ideal long-term results after ablation of LVS IVAs from within the great cardiac vein/anterior interventricular vein.