Hemodynamic classification of paravalvular leakage after transcatheter aortic valve implantation compared with angiographic or echocardiographic classification for prediction of 1-year mortality.
Simon SchoechlinTim BrennemannAbdelhakim AllaliPhilipp RuileNikolaus JanderMartin AllgeierMichael GickGert RichardtFranz-Josef NeumannMohamed Abdel-WahabPublished in: Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions (2017)
ARI did not help identify PVLs that are relevant to 1-year survival. Angiographic assessment during the procedure was less predictive than echocardiographic assessment before discharge.